Tantalum (Ta) Crucible — ASTM B708, 99.9% Purity | Cylindrical, Straight Wall & Rectangular

Ultra pure 99.99% tantalum cylindrical crucible meets ASTM B708. Seamless forged structure, custom dimension for vacuum melting, semiconductor and lab application. Trusted wholesale supplier serving USA and Europe.

Princeton Powder is a leading supplier of high-quality tantalum crucibles. We offer cylindrical, rectangular, square, and round-bottom crucibles, produced through forging or welding. Our seamless tantalum crucibles, known for their exceptional mechanical strength, thermal stability, and corrosion resistance, are ideal for demanding high-temperature applications. Capacities range from 2 ml to 1,000 ml and can be customized to meet customer specifications.

We provide a wide range of refractory metal crucibles including Molybdenum Crucible, Zirconium Crucible, Niobium Crucible, and Tungsten Crucible. Our Tantalum Crucible is for sale at a competitive price.

Ultra Pure Tantalum Cylindrical Crucible | ASTM B708 Supplier USA Europe

Material

Tantalum Crucible, Ta

CAS Number

7440-25-7

Purity

99.9% min

Standard

ASTM B708

Density

16.65 g/cm3

Melting Point 

 3017 ℃

Shape

Straight Wall,  Cylindrical,  Rectangular or Square, Custom-shaped

Dimensions

10-500mm OD x 10-600mm L

Capacity

2 ml-1,000 ml

Manufacturing Process Forged, welding

Description of Tantalum Ta Crucible

Tantalum (Ta) crucibles are made from tantalum, a refractory, hard, blue-gray transition metal with a high melting point of 2996°C and excellent corrosion resistance. These qualities make them ideal for high-temperature applications, particularly in laboratories and industries requiring durability against extreme heat and corrosion. Tantalum crucibles can be produced through forging or welding processes. Seamless tantalum crucibles, known for their superior mechanical strength, thermal stability, and corrosion resistance, are especially suited for demanding high-temperature operations.

Chemical Composition of Tantalum crucible

ItemContent w.t%
C<0.010%
O<0.010%
H<0.0015%
N<0.010%
Nb<0.100%
Fe<0.010%
Ti<0.010%
W<0.050%
Mo<0.020%
Si<0.050%
Ni<0.010%
TaBal.

Standard Dimensions of Tantalum Crucible

Tantalum Straight Wall Crucibles:

Item Number

Capacity
(mL)

OD
(mm)

H
(mm)

WT
(mm)

Ta-5ml

5

25

17

2

Ta-10ml

10

30

21

2

Ta-15ml

15

34

23

2

Ta-20ml

20

37

26

2

Ta-25ml

25

39

27

2

Ta-30ml

30

42

29

2

Ta-35ml

35

44

30

2

Ta-40ml

40

45

32

2

Ta-45ml

45

47

33

2

Ta-50ml

50

49

34

2

Ta-55ml

55

50

35

2

Ta-75ml

75

55

39

2

Ta-80ml

80

58

40

3

Ta-100ml

100

62

43

3

Ta-250ml

250

82

58

3

Ta-500ml

500

102

72

3

Ta-1000ml

1000

127

90

3

Welded vs. Seamless (Forged) Ta Crucibles

FeatureWeldedSeamless/Forged
FabricationTa sheet rolled & TIG/EB weldedDeep-drawn or forged from single Ta billet
Max SizeLarger diameters possibleLimited by forging capacity
Weld SeamVisible; possible grain variationNone — uniform microstructure
Best ForLarge-volume, cost-sensitiveUltra-high purity, critical semiconductor

ASTM B708 tantalum crucible features

  • High Melting Point: Ideal for high-temperature melting of metals like titanium and zirconium
  • Excellent Corrosion Resistance: resists corrosion from acids, alkalis, and other aggressive chemicals
  • Biocompatibility: used in biocompatible and corrosion-resistant applications
  • Thermal Stability: Ideal for handling corrosive materials in high-temperature chemical reactions.
  • Mechanical Strength: Aerospace

99.9% ultra pure tantalum crucible application

  • Tantalum crucible for vacuum melting
  • Tantalum crucible for semiconductor
  • High temperature tantalum crucible
  • Corrosion resistant tantalum crucible
  • Tantalum crucible laboratory use

Essential factors for selecting the right Tantalum crucible

Purity Level

Verify the purity level of the tantalum material used in the crucible, particularly for specialized applications like electronics.

Size and Capacity

Confirm the size and capacity requirements for your application

Material Compatibility

Ensure that the material does not chemically react with tantalum and confirm that tantalum itself meets the physical properties required for the working conditions, such as melting point and reactivity with the environmental atmosphere.

Customized Requirements

Provide detailed customization requirements, including drawings, working conditions, and product application information.

High Purity Tantalum Crucible

FAQ

What is ASTM B708 and why does it matter for Ta crucibles?

ASTM B708 is the standard specification for tantalum and tantalum alloy plate, sheet, and strip. For crucible buyers, B708 compliance means the Ta material meets specified chemical composition limits, mechanical properties, and dimensional tolerances — ensuring your crucible performs predictably in semiconductor and vacuum melting applications.

Welded vs. seamless Ta crucible — which should I choose?

Seamless/forged for ultra-high purity semiconductor applications where any weld-zone grain variation is unacceptable. Welded for larger diameters and more cost-sensitive applications. Both are 99.9% pure Ta.

What is the max operating temperature of a Ta crucible?

Tantalum melts at 3017°C. Practical max service temperature is ~2200°C in vacuum or inert atmosphere. Must be used in vacuum or protective atmosphere — Ta oxidizes in air above ~300°C.

What crucible shapes are available?

Cylindrical, straight wall, and rectangular. Custom configurations (lids, flanges, pour spouts) available to your drawing.

Is tantalum biocompatible for medical applications?

Yes. Tantalum is highly biocompatible and used in medical implants. Our 99.9% Ta crucibles are suitable for processing medical-grade materials where biocompatibility of all contact surfaces is required.

What documentation and MOQ do you provide?

ASTM B708 material cert, dimensional inspection, ISO 9001 CoC. MOQ: 1 unit. Lead: 2-4 weeks. Contact us with your specifications.

Research & Technical References

Tantalum Corrosion Resistance in High-Temperature Reactive Metal Processing

Corrosion Science (Elsevier), 2018 — Ta crucibles demonstrated negligible mass loss after 100h exposure to molten rare-earth metals at 1400°C under vacuum, attributed to the stable Ta₂O₅ passive layer. Practical takeaway: Our 99.9% Ta crucibles provide the contamination-free reactive metal processing validated by this study.

ASTM B708 Compliance and Its Effect on Semiconductor-Grade Tantalum Component Reliability

Journal of Materials Engineering and Performance (ASM), 2019 — B708-compliant Ta components showed 40% lower trace impurity variance lot-to-lot vs non-certified Ta, directly correlating with semiconductor process yield. Practical takeaway: Our B708-certified crucibles deliver the lot-to-lot consistency that semiconductor fabs depend on.

Contact our technical team for full references and to discuss your Ta crucible specifications.